How earth fault & earth leakage equvpment are works?
Answer Posted / namrata
the earth fault when there is no neutral grounding jn the
system.
| Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????
what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??
How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.
i need list of swg(standard wire guage) or area of conductor v/s current carrying capacity of conductor copper & alluminium...
How can I known multiplying factor .without multiplying table
what is vtg limit of earth and neutral at transformer side?
how many current required for hypo test
I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?
Why using synchronising methed in DG's sets?
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.
What is rotating magnetic field?Discuss elaborately.
can i use the six sigma method which is used in management area, in state estimation of power systems?
why in the three pin plug all 3 pins are cutted ?
What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?