What is the
effect of
impedance on the
heat losses in
case of AC
system??? Does
heat losses
really depends
on the impedance
or depends only
on resistive
component
only..??
Answer Posted / lalitha
imp Z= R+JX and T is direstly proportional to R...therefore
heat losses increase with imp
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?
what is the reactive power what is the use of it in system
When we connect the large capacitor bank in series ?
What is a advantage of Self Reset Lockout ? On Fault breaker get trip & fault no longer exist then self reset lockout how inform us?
what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:
What is meant by short-pitched winding?
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
iam working in power plant. In hot places tube lights are glowing at the end portion only. what is the reason for that?
Can any body tell gulf interview question for experienced electrical engineer ?
why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?
i have interview in Pepsi company what type of question will ask please send the question and answeer
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.
what is meant by LCR meter? where its useful ?