why we choose 50 or 60 hertz not other value for the power
system?
Answer Posted / bala
because the internal current goes up and this might cause faster deteriation of the insulation on the wiring, which causes shortcircuit and this may lead to fire, which can burn down your house!
What happens:
In transformers (like input transformer of the equipment) the current goes up.
In motors (like cooling ventilator or compressor) also the current goes up, the turns of the motor depends on the frequency, which means the turns are 17% higher if you go from 50 Hertz to 60 Hertz and 17% lower if you go from 60 Hertz to 50 Hertz, plus in this case the internal cooling is lower!
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
The series field winding has low resistance while the shunt field winding has high resistance. Why?
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?
What is center gravity load in substation?
What is difference between start imitation and start interlock for 3 phase motor protection ?
What is slip in an induction motor?
1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor
what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.
what is consequences of neutral and earth connect?
why swinburnes test cannot be performed on series machines?explain
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
how rectifier transformer work in electroststic precipetatore(esp?
Briefly describe means used by electricity suppliers to influence the flow of active and reactive power in power networks (one for each type)?
Shall I use 40A semiconductor Fuses in 32 A SFU ? Frame size is same. What Happen if Fuses burn on SFU?
Difference between Earthing Truck & Earthing trolly for HT panel