Why screen of the screened cable not earthed on both the
ends of cable

Answer Posted / k.prakashchandra

To avoid the circulation of current in the screening due to
induction

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible

1345


temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%

1493


In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.

1333


my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking

886


-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.

1358






wht is embedded systems? what is new inthis field?

1546


How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.

1866


After synchronization with grid what is the demand value QKVAR and how we will maintain that?

1795


Describe the test procedure to determine the vector group

1597


specify the inbuilt protections in DG

1616


Is electro plating what type of load whether resistive, inductive or capacitive loads

2903


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

1676


Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!

1308


draw a circuit diagram connecting transformer OLTC- RTCC- VCB-Marshalling Box otherwise Explain in words

22130


what is servo motor and how it works?

1771