How to find the maximum load, that can be supplied by a
transformer.....
Answer Posted / shailesh tankni
the best method of finding the maximum load that can be
connected to transformer is phantom loading test..
in this test separately the current capacity and voltage
capacity are measured without actual loading of transformer..
the advantage of this test is that for large capacity
transformers the actual loading cannot be done as the total
load is very very large so this method is adopted..
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the Earth Voltages in Power Plants, Sub-stations, Industries, Residential & Commercial Buildings.
what type of questions are asked and howmwny questions belong this catagory?
In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??
why the carbon brushes are broken in srim while the motor runningtime
what is the significance of tan&delta and how it performed in power transformer
hi,every one, i have to write the search paper on "performance policy optimization" of NGN (next generation networks). i need the material on this topic. can any body help me. please tell me any useful site where the good material is available and name of any reference book. it should be a great help for me.
How will polarity test of Dy5 Transformer ?
How to calculate cable size by using load.?? Any formula...
What is a Phase shift meter? Where can I get one?
How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?
What are the limitations of Kirchoff's laws?
what is the difference between switch yard to residential area.and how much required it.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Define active filter?
how the testing of protection CT Testing done through Primary injection kit please describe in detail procedure...