Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if dc excitation is used to produce manetic flux in rotating
machines then ehy it is not used in transformers.

Answer Posted / shailesh tankni

in generators or alternators dc supply is provided to the
field along with the mechanical external force for rotating
the field winding. in this way stationary field is used to
produce rotating field which produces rotating flux and
excites the armature winding. so it works on the principle
of faraday's law of induction and provides excitation in the
armature winding.
but in transformer there is no moving part and hence if dc
supply is applied to it there will be no change in flux and
no excitation is produced in secondary winding.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Connection diagram for KW meter and  Kva meter

2315


HOW MANY TYPES OF FUSE?

2082


An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1405


An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?

2131


how to ctrl motor by use of ac or dc drive.plz explain evdintly

2023


What is reactive power and where it is used.

1677


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1894


What is the power factor of an alternator at no load?

1317


What is the function of attenuator in cro?

1180


What is the tension required for the 25000 CFM AHU belt

2457


When we connect the large capacitor bank in series ?

1075


how unidirectional torque is produced in DC motor?

6779


What are reasond for high wattage in single phase induction motors

1865


What happen if 200 KVAR capacitor connected to power continuesly?

2113


what is meant by 3rd hormonics ?

1845