Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

sir , what happen if we decrease ( approx 3 inch ) the
lenth of shaft in 110KW Induction , three phase motor.

actually a 110KW motor is couppled with star couplling to
120TR compressor. When we doing maintenance in compressor
it is required to skid the motor backword and resulting dis-
alightnment . so we want to change the tyre coupling in
place of existing coupling. so it is required to cut off
the rotor aprox 3 inch form driving side.

Answer Posted / k.prakashchandra

Cutting shaft short will not affect anything including
dynamic balance

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

2- What are the percentages between excitation currents in phase (R, S and T) in ∆ and Ỵ connections in excitation Current test in transformers?

2067


What are books to be referred for KPTCL exam?

3724


Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1780


Draw a SLD of HT distribution EB grid up to users Transformer?

6247


how to size H.T & L.T Panel ?

2184


how does an centrifugal and screw type chiller will work. which chiller efficiency is high and why.

2343


what is the main parts of transformer? how it is functioning? pls giv the ans briefly.

2015


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

2037


ho can we calculate the conductor insulation value according to their ratings like voltage,current etc.how insulation value related with voltage,current and power of amachine

2154


direction of tarbine& genrator

2133


pls tell me about ups internal connection & we have given only 3 phase supply to ups system how get 4 wire (R Y B N )

2801


why HT armoured cable does not glanding

4315


what is maxemo work permit procedure

2252


What is the function of probe in cro?

1261