Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the drawbacks of HVDC system?

Answer Posted / mahesh v p

very difficult to convert high voltage dc to ac,and is also
expensive.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the acceptable value of TAN DELTA and dissipation factor for 11kV, 1.75HP Motor?.

4238


Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?

4522


Can a generator runs after getting 1st stator earth fault.

1474


As a electrical engineer.. what are the basic norms should follow in transformer oil testing.. 1.What is the Electrode type? 2.How long time you will give for oil testing?

3716


How to use computer cpu ups use for home inverter circuit board

1837


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2177


draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it

2769


what is the basic need of domestic loads 1- voltage 2- current

2174


What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?

2207


what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv

2345


how are reversing the direction of rotation of dc motor

1818


Keywords: Die, Card, Coin, B/N 2 To 12

1328


how to operate and maintenance of 1500 kva diesel generator set

1860


Circuit diagram of tube light without starter using electrical choke

4171


Why is remote backup preferred to local backup?

2118