Why fuel tanks to be earthed ?
Answer Posted / manohar v. tawade
All in one is the reason for discharging static energy.
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT
difference between a diode and thyristor?
sir i used 3 hp of motor for spraying pump, other home light and other home items which size of allminium pvc wire ix used
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.
WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
how to calculate slip ring induction motor stator and rotor currents??
relation between power station capacity and voltage level?
what is current check gurd relay?
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing
Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com
How to calculate the electrical load for a standard telecom BTS shelter and choose the DG set capacity for the same load?
What is the difference between voltages or potential difference? And what are they?
What will be the current if the resistance total in a series circuit doubles?