why transformer has more efficiency compare to rotating
machine?
Answer Posted / harjeet singh
transformers where the primary and secondary windings were
of identical inductance, giving approximately equal voltage
and current levels in both circuits. Equality of voltage
and current between the primary and secondary sides of a
transformer, however, is not the norm for all transformers.
If the inductances of the two windings are not equal &
their is no any firction losses in transformerso trasformer
has mor efficiency as compare to rotating machine.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
State the factors, for the choice of electrical system for an aero turbine.
1.what is the difference between ct and cvt? 2.what is the difference between pt and cvt? 3.what is the difference between relays and circuit breakers?
which is better to use svc or synchronous condenser why ?
what is quality factor in series resonance circuit and calculate the factor of voltage magnification? how it happens?
how to calculate fuse rating for a motor
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
How good are you in resolving the commercial issues to Employer's advantage?
how to calculate the earth mat design in 132 kv substation yard ????
Which type of a.c motor is used in the fan (ceiling fan, exhaust fan, pedestal fan, bracket fan etc) which are find in the houses ?
What is the minimum IR value of HT/ LT cable? Pls post separetely!!!!!
Why the symbol of register is "zig zag"
xfhnchncv?
Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<