what is pressure relief valve in D.G ?state its function?
Answer Posted / dinesh (techie.dinesh@gmail.co
whenever the pressure in the transformer tank increases, the
pressure is released by PRD. PRD reduces the pressure by
splashing the oil outside the tank, i.e the PRD has a preset
value, if the value exceeds beyond the preset value, the prd
comes in action.
and when the PRD reduces the pressure, the vertical
flap/flag mounted on the PRD raises. although the pressure
is reduced, the flap wont lowered, it is used to indicate
the supervisor/operator that the pressure value has
increased. once the operator get noticed, he will manually
lower that flap
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what mean by analog ,digital,numerical meters and relays? say the example?
How to calculate no of EARTH PIT? Describe the formula as per IS standard?
How to calculate the input cable rating for 10kva ups (3phase input and single phase output and also 3phase output, battery rating 65Ah)provide the formula also.thnx
what is counter poise conductors
what will happen if OLR CT in all phases are short circuted
it is in our knowledge tht right plug of supply of residential suppy system is phase n other is neutral...howevr the battery charger of mobile works in both ways...i mean it is not restricted in only one direction.ny of the holder of charger can hav phase .so y is it not lik tht phase of supply must b connected 2 phase of charger...?
can we do the star delta connection of capacitor for 3- phase motor starter.
why we take movement of rotor always in counter-clockwise direction in 3-phase induction motors?
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
sir i had plane to do some project with the base of hopkinson test in AC supply its possible
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What is the function of electron gun assembly used in crt?
how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???
what is the difference between unarmoured & Flexible cable? How to identified?
what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?