What are all the type of vibration measurement measuring in
turbine, what is the output of vibration sensor.
Answer Posted / azam
there r diff companies which make vibration sensors and
their measurement and control panels (B&K germany)
output is in mV.
| Is This Answer Correct ? | 7 Yes | 9 No |
Post New Answer View All Answers
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
for oil & gas industries which zone is normally preferred? why? give its example?
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
how to work static pressure sensore how to work dpt
How hart protocol can be connected with control valves?
How works weighfeeders in cement industry? what is the working principle?
i have steam drum height 1000mm. and i want to placed the transmitter below the tap.how i calculate.
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
How to calibrate Toxic gas detector?
how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line
How ejector(or)evactor air pump is working in thermal power plant?
Capacitance, resistance ( colour coding ), parallel & series circuits.
how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?
I want to apply for the universities in US,but i got the GRE score of (650+300=950)TOEFL 69/120.Is this score sufficient for applying universities please i am married i need to go to US because my husband didn't get H1 yet.please send me suggestion
2. What is ultrasonic flowmeter?