why d.c. supply is given to the primary side of generator?
Answer Posted / austin kpoto
Derived from a closed loop system from alternator, when
exciter rotate rectifer induce dc voltage. Exciter diode
convert dc current from diode to rotor main armuture to
produce magnetic field to the primary side of the
alternator.Poles turns produce minus and plus sign from
main armature than alternator send dc current to AVR.
Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
What is the difference between a Root Locus plot and a Bode plot?
redundant connection in contactor?
How to calculate capacitor bank size at a load 800kVA.
why in an industry; machine having rated 200 h.p stopped after power factor is maintained above 0.97 lag by control panel in view-of energy saving
Is it a better option to procure screw type air compressor rather than reciprocating air compressor?If so, what is the reason?How should we select an air compressor(100 CFM)? Please mention the important parameters of air compressor.
what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv
how to calculate mf when meter and cTPT detail are given
y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..
why asa method ZPF method is more accurate than ASA method?
3ph motor running with unequal kw and different pf what are the reasons
1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?
i have interview in Pepsi company what type of question will ask please send the question and answeer
how to calculate micom relay earth falt time and current sertting
What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?
I FINISHED MY B.TECH IN EEE . I AM IN NEED OF A GOOD TRAINING INSTITUTE TO DO COURSES .. CAN ANYONE SUGGEST GOOD CENTRES IN TAMILNADU ,BANGALORE ,OTHER AREAS???????