Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If 11 KV breaker on the primary side of a 11 KV/3.3 KV 12.5
MVA transformer can be installed at a distance of 1000 mtrs
through a 11 KV cable. If no what are the probable reasons.

Answer Posted / bala_vlsi

1000 m is not possible because the voltage drop will be
very high so you will consider lot of cable and it is not
practical . if want this system you should consider
overhead line method

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.

2000


How to Calculate KA Rating of Main LT Panel

1756


How work of capacitor in dc supply...???

1609


How to measure size of cable on a given load

1840


Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2361


The electromagnetic torque developed is proportional to what in a D.C series motor?

1178


why starting current is high and resistance is almost 0 during the starting of motor dc motor...?

1736


how is calculated the quantity of weight in hot test xlpe?

2514


What are the advantages of vscf wind electrical system?

1094


CAN ANYBODY PLEASE TELL ME HOW TO DESIGN A SERIES REACTOR FOR LIMITING SHORT CIRCUIT FAULT CURRENT??

1892


state the disadvantages of carbon filament???

2943


is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details

2000


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2820


What are the three major categories of error?

1232


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

3247