Answer Posted / yasir wani
coz of eddy currents flowing in the core , and leakage
currents from leakage inductance to ground
| Is This Answer Correct ? | 6 Yes | 5 No |
Post New Answer View All Answers
Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?
Which is the oldest hydropower plant in india?
what is the prinsiple of dc motor and construction and working ,application of dc motor.
from which subjects most of the technical que will b asked for hpcl(electrical).pls help me
what is the acceptable limit value for Desolve Gas Analysis/
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is the formula to calculate the size of Aluminium and copper cable?
how to measure earth resistance of a substation
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
how external lighting design? please give examples?
what is the working principle of a DG Set, Alternator, & exiter
which connection is safer series or parallel?usually which connection we prefer at home?
Either the Armoured Earthing strip of HT 3 core cable have to pass through CB CT or not , why ???
I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.
What will be electrical cost per sqft for IT building (basebuild and fitout)and for residential township?