what is load shedding

Answer Posted / sarad bashyal

demand of power = supply of power -no load sheeding
if supply of the power is higher than demand then at this
time generated power should be decrease in power station by
checking the frequency.
if demand of the power is greater than supply of the power
then there must be cut some feeders in order to balance
the electric system. cutting some load feeders to balance
the electric system is callted load shedding. if we do not
balance the system then anytime frequency will decrease or
increase in the system and finally system will collapsed
and some where it is also called blackout. when system
collapsed/black out that time all the power station which
are connected in grid are are stooped.

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help

1102


Starting Time of LT & HT Motor

1468


why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?

1586


what is is the potential diffrence between two phase ?

5357


how to calculate the breaking capacity of different breakers.

1684






What is the drawback of static coefficients?

867


how many electricity poles are there and what are the names and their sizes.

1427


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

1733


What are the application of filter?

646


List examples of voltage source?

603


If increased the frequency up to 1000 then what changes shows in voltage?

1966


Hi everyone. Some Generators uses 3-Pole breakers with extra contactors for Neutral. Some uses 4-Pole. Why so? What is the idea behind this? Thanks in advance for the solution. Kr.

1604


How can i calculate the Breaking capacity of molded case circuit breaker, is the breaking capacity of CB for Diesel generator shall be less than grid supply's breaker ?

1699


What is the difference b/w fanuc alpha series 16i and 18i controller. what is stand for i

1584


How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.

1705