Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

When batteries are connected in series the voltage increases
but the current remains unchanged, how can this be?

When you consider ohm's law. i.e.
If voltage increases, current increases, providing
resistance remains the same.

Answer Posted / naresh kumar dhal

In series ckt voltage sourse is additive and current
remains the same.It is the property of a series ckt.

Ohms law has no relation to the abovw question.Ohms law
applicable to pure resistive ckt only but physical
condition should be constant.

You have written a wrong thing that resistance remains the
same.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

any idea abt REVERSE METERING concept.........?

2220


How to calculate multiplying factor of dc energy meter

1656


Advantages of using generator circuit breaker (GCB) scheme in a power station ?

5255


What is 100% protection of generator? Why 100% is not used but 95% is generally used?

1027


Hello Friends, How can we recognize the CT Star Point is S1 or S2 in case of Electro Mechanical Relays and what is meant by Restraining coil in relays and what is the purpose of that.. thank you in advance..

2149


What descriptive information does the NEC require to be marked on all conductors?

1992


Write the force balance equation of ideal spring element.

1241


How is the gain affected by the introduction of feedback in a control system.

1151


Why open circuit test of transformers is conducted at rated voltage??Why not any other voltage??

1643


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

2058


What is Harmonics how it is produced and what is the method to control the same

2257


why electronic instruments is more favorable than electrical?

1949


WHAT IS MEANING OF Gg & Gg IN hrc FUSE

3263


Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar

1799


What are n circles?

1074