Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In Increasing temperature why thermocouple used and RTD is
not used. Both RTD and Thermocouple have in Range of uses.

Answer Posted / naresh patil

bcoz linearity of thermocouple is greater than RTD & having
range at 0 degree celcius resistance will be 100 ohm.

Is This Answer Correct ?    2 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to Calibrate Vibration Probe (Axial, Redial) in field

1091


plz send me general of ongc

1888


What is the difference between modbus,fieldbus & profibus

2359


What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.

2966


How do you identify an orifice in the pipeline?

1184


Explain the burnout feature.

930


What are the error values can accepted in flow transmitter calibration?could u give any formula for this?

1842


What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch

2144


What are different types of cable?

1042


May I have a brief note above the voltage barriers? Whats is the purpose? Please mail me if you've operational details, mail id: rajkumar.diice@gmail.com

2078


What are the types of control valves available

2030


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1337


How does your previous experience relate to the job you are applying for ?

1963


How to Calibrate Interface Level Troll in field

1274


How to calibrate an pressure gauge with yantrika test bench?

2840