Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are using starter

Answer Posted / thirudinesh1982

in the motor initially stable when the motor get power then start to rotate at the time starting current 6 times greater than normal current because (there is no back emf at the initial). So we protect the motor from the inrush current to use the starter.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

for a 400kv t/m line with 10 ampere current will corona occur?

2144


what will happen if earth of 33 kv cable (earthed system) is not connected to earthing pit?

1978


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1402


What is the difference between cylindrical-type and sandwich-type winding?

1406


how we arrange the hv side with delta connection in case 33/11kv of transformer.

1945


plz send me the placement interview question and answers of whizchip(technical and apttitude)..i have an interview in next.

4956


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

2019


How to calculate the External Resistance required for 60HP slipring motor in case no any data of the Motor is available???

2009


all interview questions with answers of ntpc (2000-2009

2166


To prove the capacity of a 10MVA transforemr with 6.5% impedance by a short circuit test how much power is needed to inject an impedance voltage if we have to arrive for its rated current?

1855


Why are cables rated for 40 KA for 0.25 Sec fault current rating?

1883


What is depreciation factor?

2218


Dear sir, How to calculate 3.5 core pvc aluminium armoured cable meter wise carrying amps rating.Please give the solution with a good example.

1806


Where can I get Iidian straderd specifications for electrical items or works in web? please help me.

1958


What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?

2115