What is the difference between short circuit and overload
currents?
Answer Posted / crosswind
I agree with answer #8 short circuit have diffrent types of
fauls L-L, L-G, 3ph S/Cetc seee iec-60909.the S/C current
when to hot wires (un-grounded) wire make unintended
contact with each other; p 2 p S/c has thus been created.It
created unbalance fault of the system.This means
interruption of the system.... unlike Overload current is
interrrupted the load itself by means of overload
protection setting (Thermal Load) relay operated well to
trip. This mostly different not the same ..In shotr S/c
interrrup the system Max. interrrupting value (Ka) while
Overload currents happens only in motors stated by answer#8
Additinally,S/C analysis is onthe importance in power
system study because it protec the whole system by the
right choices of prtection device and by the right study of
devise -coordination the tripping curve will not overlap
with respect to the point of S/C fault who will be the
first to tripp rather than the last breker it was so called
the selection of the right tripping ( Long & Short Circuit
delay)
| Is This Answer Correct ? | 4 Yes | 14 No |
Post New Answer View All Answers
What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.
How to calculate the External Resistance required for 60HP slipring motor in case no any data of the Motor is available???
Which type of motor is used in trains, what is the rating of supply used explain working principal?
What is the count of hvdc transmission lines in india?
"TRANSFORMER MODELING AND ANALYSIS" MEANS WHAT AND WHICH TOPICS U READ IN THIS
Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.
what is the minimum (Common factor) insulatin resistance of the following a, 4mm sq wire b, cable from 50 mm sq to 800mm sq
How eddy current generation support the idea of train braking?
Which capacitor is preferred for high voltage and frequency?
what are the breakdown voltage rating of mini- curcuit'transfarmer!
State thevenintheorem?
Define phase lag and phase lead?
I need the recommended size for a 3 phase transformer at 13.8 KV Primary and connected loads of 3000 kVA at 4200 volts and 2375 kVA @ 480 volts AC.
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value
What are the uses of stepper motor?