what is the principle to generate energy from water or coal,
plz define the step by step how & when electricity energy
start from resource area to ours home meter & separate & how
meter read the voltage or current?
Answer Posted / ajit g. k.
Please give some respect to this site. This is not a
homework site. Every electrical engineer is bound to know
the answer to this question. This thing is taught in 10th
and 12th standards. kindly perform a google search or ask a
12th standard student.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
How to know any size of cable if there are not written on cable? Answer must be theurical not by experience.
what about the power of wattmeter at starting and loding?
What is the permissable nutral current of three phase system as per IS standards?
If more than rated DC voltage appears across trip coil of the breaker, what will happen? e.g. in 110V DC circuit system, if voltage across battery terminal showing 121 V
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.
how invertor convert the dc into ac give brif detail
what could be the RMS value and average value of a 4 phase sine wave?
How I can Compare 120v/60Hz versus 220v/50Hz ? Please tell me both advantage and disadvantage ......
mention hazard experienced during installation
Differentiate between ideal and non ideal current sources?
Define phase cross over?
what is differnce btwen lll and lllg faults
how can decide the current rating of oltc
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?