Though transformer consist winding which usually cause
reactive power change in both generator and motor but it
wont affect reactive power passing through transformer why?

Answer Posted / vijendra joglekar

The questions itself wrong because the transformer doesnt
consumes real power because there is no rotating part in it
it only introduce working flux but if you take the
generator or motor it will consumes the real power

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2133


What is Phase margin?

652


75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?

3278


how to know the diffrential relay setting of 06mva step- down (delta-star)transformer?

1533


What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?

1533






placement paper samples of mspl company

1518


Whether power factor should be high or low? Why?

663


defination of lines

1542


Sir, I m 3rd year student 4m DCE and want to do internship in siemens or l&t or any other mnc related to electrical engineering. please tell me the procedure 4 same and oblige me

1525


Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?

1478


what is the basic construction diffrance between servo motor ans sqiralcage induction motor

2018


how will calculate the safe starting current of 3-phase squirrel cage induction motor?

1450


how to calculate micom relay earth falt time and current sertting

1847


when 20hp 3 phase motor start no load condition in star or delta connection.find current and write formula.(tariq)

1532


1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.

1488