Why dont we get shock while testing for voltage with a line
tester?
How the bulb inside the tester glows while testing with
tester coz we are totaly isolated from earth or we are not
giving close path for the current to flow?
Answer Posted / deepak
inside the tester their is a resistor which limits the current flowing through it hence we dont get shock. n we touch the finger only for complete the ckt.
| Is This Answer Correct ? | 30 Yes | 3 No |
Post New Answer View All Answers
how much maximum load a 2 core (Single phase) 16mm aluminium wire can take ?
state basic meaning of 'INDUSTIAL AUTOMATION'?
What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?
If UG power cable both ends are to be earthed or what? If not why?
Is single load(eg: three phase motor) having all the components like positive,negative,zero sequence components during fault condition?
what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?
what is the power rating of CPU, CRT type moniter, LCD type moniter,scanner Approx.
1. The DC generaror,s induced output emf is connected with a DC motor(as load). when increasing the load of the motor by using brake drum or any way. what are the parameters will changes in both motor and generator(voltage, current, resistance, frequency, speed, torque, power, flux etc...) 2. Similarly for AC generator and AC motor 3. similarly if using DC batteries instead of DC generator, What happens?
dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish
What is the classification of hydro projects based on installed capacity?
my b-tech percentage is 50%. what answer will satisfy the hr ?
and gate circuit diagram,amplifier circuit diagram
how to calculate singlephase motor efficiency?
How will you utilise electrical power? You can start from the generating station.
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.