CAN ANYBODY EXPLAIN WHAT ACTUALLY MEAN BY THE PHASE
DEFFRENCE? R,L,C CIRCUITS?
Answer Posted / kundan
Two oscillators that have the same frequency and different
phases have a phase difference, and the oscillators are said
to be out of phase with each other. The amount by which such
oscillators are out of step with each other can be expressed
in degrees from 0° to 360°, or in radians from 0 to 2π. If
the phase difference is 180 degrees (π radians), then the
two oscillators are said to be in anti phase IS CALLED PHASE
DIFFERENCE...
resistor, an inductor, and a capacitor,
connected in series or in parallel. The RLC part of the name
is due to those letters being the usual electrical symbols
for resistance, inductance and capacitance respectively. The
circuit forms a harmonic oscillator for current and will
resonate in just the same way as an LC circuit will. The
difference that the presence of the resistor makes is that
any oscillation induced in the circuit will die away over
time if it not kept going by a source. This effect of the
resistor is called damping.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the purpose of using filters in a protective relaying scheme?
any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?
How dia computation perfomed in cold rolling mills .
What is synchro?
What are the various types of rotor used in the alternators?
What is the power factor of an alternator at no load?
Is there any standard guidelines/Criteria to design NGR/NGT.?
please send me previose rrb junior engineer qustion papers
What is Surge Capacitor? Why it is use in Generator Circuit Breaker?
We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.
What is dynamo function in DG sets and draw block diagram?
how to copy from plc ge fanuc versamax series,all input and output, adress, and printout.
what is the solution for meger test failed the MV cable?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
why do we not use equivalent voltage source in negative sequence equivalent ckt.