What is static Device & Mechanical device? Is transformer a
static device?
Answer Posted / pramod koshy mathew
static device is a device which does not cnsistin of any
moving instruments.
mechanical devices consisting of moving components to creat
force.
since transformer does not consisting of any movings
components for creating flux it is consider as a static
device
| Is This Answer Correct ? | 42 Yes | 8 No |
Post New Answer View All Answers
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
why output is out of phase in case of common emitter?
HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....
Define filter?
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.
when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?
WHAT HAPPENED DC SERIES MOTOR FIELD WINDING OPEN. CAN POSSIBLE.
What are unstable systems?
Why do you have to use Protecion relay with the function MTB ( Mechanical Trip Button ) for electrical system.
During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?
What are the advantages and disadvantages of the dc motors?
how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.
what is the importance of earthing system on the generators big capacity and small?
When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?