In Siemens S7-300 PLC, what is funtion and funtion block ?
What is the difference between them ? When to use function
and when to use function block
Answer Posted / william lobo
support.automation.siemens.com
you may approach them for your answer if it is related to
specific equipment used by yourself.
vi S7 Standard Functions Part 2 C79000-G7076-C113-02 The
following functions and function blocks are described in
this manual:
Function or Function Block
Number
Page
oftware Timer On Delay—Retentive (TONR) FC80 5-2 Indirect
Block Move (IBLKMOV) FC81 4-2 Reset Range of Outputs (RSET)
FC82 1-2 Set Range of Outputs (SET) FC83 1-6 Add to Table
(ATT) FC84 2-2 First In/First Out Unload Table (FIFO) FC85
2-4 Table Find (TBL_FIND) FC86 2-6 Last In/First Out Unload
Table (LIFO) FC87 2-9 Table (TBL) FC88 2-11 Move Table to
Word (TBL_WRD) FC89 2-13 Word Shift Register (WSR) FC90 3-2
Word to Table (WRD_TBL) FC91 2-15 Bit Shift Register (SHRB)
FC92 3-4 Seven Segment Decoder (SEG) FC93 6-2 ASCII to Hex
(ATH) FC94 6-4 Hex to ASCII (HTA) FC95 6-6 Encode Binary
Position (ENCO) FC96 6-8 Decode Binary Position (DECO) FC97
6-9 Ten’s Complement (BCDCPL) FC98 6-10 Sum Number of Bits
(BITSUM) FC99 6-11 Reset Range of Immediate Outputs (RSETI)
FC100 1-4 Set Range of Immediate Outputs (SETI) FC101 1-8
Standard Deviation (DEV) FC102 7-2 Correlated Data Table
(CDT) FC103 2-18 Table to Table (TBL_TBL) FC104 2-21
Scaling Values (SCALE) FC105 6-12 Unscaling Values
(UNSCALE) FC106 6-14 Lead/Lag Algorithm (LEAD_LAG) FB80 6-
16 Discrete Control Alarm Timer (DCAT) FB81 5-4 Motor
Control Alarm Timer (MCAT) FB82 5-7 Index Matrix Compare
(IMC) FB83 8-2 Scan Matrix Compare (SMC) FB84 8-6 Event
Maskable Drum (DRUM) FB85 5-10 Pack Data (PACK) FB86 4-4
| Is This Answer Correct ? | 5 Yes | 7 No |
Post New Answer View All Answers
What will be the voltage regulation of a full load and 0.80 power factor lagging load transformer when a two winding single phase transformer has a voltage regulation of 4.5% at full load and unity power factor?
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%
what is size of 3phase 4wire cable to be used for 11 ton ductable A.C and how to calculate cable size for different load
if any house we instaled a 1.5 ton ac and its phase cable of wiring is installed but netrual cable of wiring not instaed. my question is that is neutual of house(for other wiring is capable for ac load or a sepeart neutrual wiring required
what is meant by poly phase induction motor ? how its operating by single phase or three phase?
What is the importance of counter based plan & how is it scheduled?
standard earthing rating for power line..
State the factors, for the choice of electrical system for an aero turbine.
WHAT IS THE DIFFERENCE BETWEEN AN ACB & mccb 7 WHAT IS THE CRITERIA WHEN TO USE WHICH OF THE TWO
If a high resistance fault occurs,then what are the changes will happen in the system?
which capacity of RCCB used for five thousand watt electricity load?
working function importance of mdc meter
Discuss the effect of sudden loading of an induction motor
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
what is acceptance test in electrical engineering.