Answer Posted / visakh v
Well data sheet is always the best choice. Other wise go for Hart...
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
What is difference between radial vibration and axial vibration explain in detail .
IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?
why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?
1.can you use SCADA instead of DCS,DCS instead SCADA 2.Difference between DCS and PLC,can their role be reversed i.e. role interchange 3.Difference between RTU and PLC
Explain PID controller tuning & any one method used for it.
hi! i want to know about mpse exam.
What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?
WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?
Questions on flow meters,few questions on HART protocol,
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
what is orfics working in main steam line. is it increase pressure, velocity of steam flow and dicrease steam flow rate. or any other
Tell about your IFFCO plant visit.
what are the values of fuel flow rate in various places in boiler.