Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why reverse power relay is used?

Answer Posted / sivaraju

if two generators synchronised and are punning parallel,
the total load divided and generator takes half of the
total load upon it.
some times because of load unbalancing one generator
shifts his total load on second generator and run as a
motor . before this condition the generator is taking load
upon him and now it will became as a load and it will run
as a motor insted of generator.
in this condition the second generator winding can be
damage, so we use reverse power relay. because the
direction changed of power , so we called it reverse

Is This Answer Correct ?    7 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why is using sensor?what is differece between photoelectric and proxmitty?

1951


How many types of instrument cables are there?

1032


Phase control and integral control are used for?

2251


Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?

1821


how can get electrical c licence.now i am working in spining mill , transformer capacity 2750KVA. SANCTION DEMAND 2250KVA. PLEASE ADVISE ME . MY CONTACT NO 09944226823

1755


What is voltage divider rule?

1122


Name of the relay of low lub oil presuure in DG sets

1990


what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel

1935


Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?

1153


What are the weight of 800KV DA,DB and DC type tower ?

3072


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2706


some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?

1698


what is the purpose of bypass mode in energy lighting transformer?

2438


what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.

2146


What is star-delta transformer?

1134