Answer Posted / sanket
YWY- IT MEAN COPPER CONDUCTOR,Y- PVC SHEATH,W-SINGLE ROUND
WIRE ARMOUR Y- PVC INSULATED CABLE..
AFWY DONT KNOW BUT U CAN FIND LIKE THIS
IF THERE IS NO MENTION FIRST IT MEAN COPPER CONDUCTOR(1)
A- ALLUMINIUM COND.(1 CHARACTER)COPPER OR ALU.CONDUCTOR
Y- PVC SHEATH (2)
F- SINGLE ROUND WIRE ARMOUR (3)EITHER F,W OR FF,WW
W- SINGLE STRIP ARMOUR (3)
FF-DOUBLE ROUND WIRE ARMOUR (3)
WW-DOUBLE STRIP ARMOUR (3)
Y - PVC INSULATED(4)
| Is This Answer Correct ? | 9 Yes | 3 No |
Post New Answer View All Answers
What if the difference beween internal and exrteranal LBB?
I want to replace the 3 KW DC motor with AC motor so what should be the rating of AC motor? Details Of DC motor to be changed with AC are - Kw - 3, Vf - 310, If - 0.15, Va - 400, Ia - 13, RPM - 2400
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
what is meant by re-rolling motor? how it differs from standard motor?
what is v/f control in VFD?
i have 500 amp inductive load of motors ,,,pleas tell me how can i calculate for capacitor bank for improving my power factor to 99 .....calcullations for capacitor bank,,,,
what is PID control in VFD drives?
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
draw the block diagram of fire alarm?
what is meant by loss of field in a DC motor? how a universal motor works?
What is the difference between security constraint unit commitment and security constraint optimal power flow?
On Which Pressure PRV is operated.
can you any one give exact mathematical relation between AC current and DC current?