why transformer ratings in kva?
Answer Posted / aryan
Since transformer is a static there will not be any
rotational losses it have only iron loss depend upon
voltage and copper loss depend upon current
for AC supply systems like generator, transformer rating is
done in KVA because of inductance present in AC . we don't
know load is resitive or inductive
it is independent there fore it is measured in kva
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
If I want to lift the water at a height 50m from ground level through two inch(diameter) metal pipe then what is the capacity of motor pump is required? is it possible in single phase supply or not?
How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.
What is the equivalent circuit of a transformer and its vector diagram?
what is value of Jin transformer
why would amp draw on neutral wire be as much as amp draw on the hot leg.
What should be the voltage between Neutral and Ground in secondary side of the step down transformer (230 V to 110 V) with no load condition?
Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????
hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused
armature winding of dc machine produce alternating emf then it convert in to dc by using commutator.But only we consider armature resistance why don't we consider inductive reactane effect?
sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.
The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power
How does PLC work for sychronising of Two or more DG sets?
how can i get the formula to find out the cable size if i know the load of main fuse protection.
Where voltage are high and current to be interrupted is low the breaker preferred is:
A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.