A 400KVA ,50HZ TRANSFORMER IS TO BE OPERATED AT 50HZ.THEN
KVA RATING OF THE TRANSFORMER?.
Answer Posted / mahendra
Its a trick quaestion.KVA rating same because transformer
change only in Voltage not frequency.
| Is This Answer Correct ? | 10 Yes | 2 No |
Post New Answer View All Answers
High speed earth switch operation with diagram
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
it is possible to rotate the DG engine dc starter with wrong polarity connections? why?
what is die electric strnth of transformer ?
how is working bearing heater?
Why should be the frequency 50 hz 60hz only why not others like 45, 95 56 or anything , why should we maintain the frequency constant if so why it is only 50 hz 60hz?
What is the purpose of stand by earth fault protection for transformer ?
How can I calculate ISF of current transformer?
what is th basic difference between a d latch time line and a d flip flop time line???
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
What is the Surge suppresor? Why using in a UDB's and How it works?
previous year paper of ntpc bhel for degree in electrical enng
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
WHTA IS LIMT OF LEAKGE CURRENT OF 11 KV 1 CORE 1000SQ.MM. XLPE CABLE.LOAD ON CABLE IS AROUND 600AMP .LENGTH 500 MTRS.
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help