difference between null and deflecting instrument.

Answer Posted / sandy

The accuracy of these two instruments depends on different
things. For the Null type ins it depends on the linearity
and calibration of the spring, while for the second it
relies on the calibration of the weights. As calibration of
weights is much easier than careful choice and calibration
of a linear-characteristic spring, this means that the
second type of instrument will normally be the more
accurate. This is in accordance with the general rule that
null-type instruments are more accurate than deflection
types.

Is This Answer Correct ?    48 Yes 20 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In power plant to measure vibration of a turbine we install sensors. Before install this sensor we have to set gap voltage. What is meant by gap voltage and its use?

1614


what is maxdna ?. explain about the software details.

3898


what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.

1728


Can Any body tell me about the Contact or Email id of any good Consultancy which help me to find a job in Instrumentation Field in India .I have Six years of Work Experience in the Same field.Please revert me back on shammi_gwalior@yahoo.com ?

1450


List three types Level Gauges with their working principles

1641






what is exact time to study dcs and plc cources

1559


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1632


What is intrinsically safe system?

713


all questions related to instrument technician in any offshore oil and gas company.

20958


What is the cascade control

990


why would you like to join our company

881


Who to difference between analog in & analog out in dcs?

1026


which type of zones used for boiler? & why ?

1427


why we us isolation barrier in hazardous area how it works to protect the area and please clarify its current flow.

1511


What is 1:1 redundancy ?

1882