Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is mcb

Answer Posted / ramendra shukla

MCB-(Miniture Circuit Breaker) This is switching and safty
device which s used in low current carraying loads to
isolate the circuit or for protuction.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if in 3-phase system voltage=440V,frequency=60Hz, current=400A. then if it is single phase then current=? and if it is single phasing then current=?

2612


WITCH CARDS IN USE IN FIRE CONTROL PANEL.

1975


Define what is difference between fuse and breaker?

1237


Is Transol transformer oil comparable to nynas nytro libra?

3164


what will be project cost for 100 kv transformer connection under oyt scheme.

3000


What is stepper motor?

1359


What are the parameters of water ( Water quality )to be monitored in Centralised HVAC ( water cooler chillers )

2121


what is size of 3phase 4wire cable to be used for 11 ton ductable A.C and how to calculate cable size for different load

4083


Dear sir, I have completed DECE in the year 1995. I have work experience in HT and LT LINE more than five years. Now i am doing BE in EEE from rajasthan university. After completion of BE,can i apply "C" Licence sir? Please reply.

1954


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

2060


what is self capacitance of inductor

2468


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

2000


how much allowable resistance that can be difference in motor all coils?

2412


why we used dc supply for field in dg set

2433


what is the advantages og idmt relay over magnetic relay??

4295