Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE DIFFERENCE BETWEEN RESISANTANCE AND IMPEDANCE
IF IMPEDANCE IS MORE THAN RESISTANCE AT SAME VOLTAGE CAN WE
HAVE RELATION DERIEVED BETWEEN THEM

Answer Posted / chandan

Resistance is the real part of Impedance,i.e. Z=R+jX.
Where R is resistance while Z is Impedance & X is Reactance.
The mod of Impedance is always greater than the value of
resistance.Since all these quantities are in phasor form
that means current through Resistance flows with zero time
difference while current through reactance flows with either
20/4=5 ms lead or lag if supply frequency is 50 hz.lead or
lag values depends on capacitance or inductance.
Active and reactive value are independent from each other.So
at the same voltage impedance willbe more than resistance by
Modulus.But if we see by phasor it may be greater or smaller
as the X value we will use.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what will happen if OLR CT in all phases are short circuted

2277


we need a ntpc previous papers

1990


What is the minimum IR value of HT/ LT cable? Pls post separetely!!!!!

2503


How much kv gas generator is needed to run 2 hp and 1 hp airconditioners, plus a refrigerator and 4 Tvs

5252


What is the role of Dedicated earthing in UPS System?

3157


I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details.

2181


11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??

1648


how does an centrifugal and screw type chiller will work. which chiller efficiency is high and why.

2344


Advantages of using generator circuit breaker (GCB) scheme in a power station ?

5323


WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT

3217


what is rating boiler

2049


State kirchoff voltage law?

1177


Is single load(eg: three phase motor) having all the components like positive,negative,zero sequence components during fault condition?

1882


What is q factor?

1166


how electrical earthing maintenance done in industry?

1687