Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between the megger and multimeter
operation ?

Answer Posted / pillay

meggar is actually a brand name, but it is more often than
not associated with with insulation resistance testers.The
meggar tester /or insulation tester actually uses a high
voltage at its terminals to do the measurements thus being
more efficient in driving In a current and than the
measurements are made.
Multimeter as the name says is used for a variety of
measurements but using basically the same moving coil.when a
high resistance or very small leakage is to be tested using
a multimeter it usually fails because of its in ability to
drive a current through a very high resistance circuit and
give a correct reading.
I would always use a MEGGAR tester for insulation testing
and a multimeter for other testing.

Is This Answer Correct ?    24 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How the over load setting for HT Motors calculated-provided in Numerical Relay

1740


How to test lightning Arrester?

842


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

1869


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2003


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1851


I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.

1648


In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??

2035


how much winding resistance of 0.75kw to 12.5kw 3ph sqwiralcage induction motor?

2919


How does a transformer contribute towards the widespread popularity of ac system over dc?

1056


explain which quantities change in the starting and the and the running condition in induction motor

1372


How to Calculate the Fault Level of Electrical Installation

2215


What is the estimated total hydropower potential of india?

1087


IF 8255 CONTROL WORD IS 94H,Tell the chip port work mode ?

2524


how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?

1680


anyone knows service engineer in chennai for EDM SPARKING MACHINE.CHMER PULSE CD 60 M.pL GIVE ANY CONTACT NOS

2367