Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can we use a control valve without positioner

Answer Posted / ajith294

here more answers reagrading positioner

maximum of the answers are 'YES' especially Answer number
10,
then i have a doubt that how control a valve at 50% open,
with out a positioner.

if there is not a positioner, how we can control the valve
( control the pnumatic pressure is applied the
actuator)?????

if a valve it using fully open of fully close condtion
throgh Solenoid Valve ( bypass the air to actuator) is on
off valve.

Without a positioner we cannot control the valve through a
controller.

thanks

Is This Answer Correct ?    1 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1934


What is the start up procedure of desalter

3617


In VVVF DRIVES VOLTAGE IS ALSO VARY WITH THE FREQUENCY. HOW? WHAT IS THE DIRECT FORMULA RELATING THESE TWO.

2313


How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.

2087


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1414


Describe how to use megger to measure the earth resistance and insulation resistance

2165


Emergency Shutdown Systems/ Plant Shutdown System.

2195


How digital input and digital output 's are working in dcs

2478


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

2126


what is the different between deflection type measurement and null type measurement in RTD?

1832


What is feed factor and its Importance in cement industry? How we can solve feed factor?.

3540


What is motion balance principle?

1113


What are the application of bernoulli’s theorem?

1093


HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?

3457


KAlman filter code for two dimension?

2013