Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are iron and copper losses

Answer Posted / bala.a

No load losses and load losses

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why all the feeders are designed in a particular manner ... is there any reason for that???

2003


what is the function of Moulded case circuit breaker, why it is called Moulded?

1599


Plz tell me how we can find that particular company has vacancy or not

2330


what is the total power generation in india?

2399


how to setting voltage RTCC panel

1713


my b-tech percentage is 50%. what answer will satisfy the hr ?

2188


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2093


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1835


why we change the direction of winding in rotor ?how we make the north and south pole?

2092


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1913


what is the circutor?why we use it ?

2406


According to underground cables a) stress b/w sheath & conductor is high b) inrush of core & conductor

2025


how can I calculate charging current of cable/overhead conductor? what is roll of voltage in it ?

3731


how to enter inverter parameter? without manaual?

2083


What is the use of oil in transformers?

1162