adspace
Answer Posted / mukesh budhauliya
These are three parameters which are required to control in
order to ensure the healthiness of boiler.
1: boiler feed water flow control
2: boiler fuel firing control
3: boiler drum level control
| Is This Answer Correct ? | 2 Yes | 9 No |
Post New Answer View All Answers
I WANT SECURITY PAPER MILL, HOSHANGABAD TEST PAPER.KINDLY SEND TO MY MAIL ID
plz you help about Que paper of mahagenco previous your,any model paper relad to it{maharastra power genration}
can any send me a forbes marshall dtron 316 manual
i hav applied for the post of engg. in iocl so please require the past test papers fro instrumentation engg please please help me and send me the papers or tell me the pattern and type of ques asked in examination......
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com
hello can yoy pls send me previous papers of jindalpower and steel ltd.....'m from instrumentation..... mani1048@gmail.com
I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..
where cascade loop use ?
What are the key features of a Distributed Control System? describing the various layers (sensor through to business system interfaces) as well as the hardware, software and security aspects of the DCS.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
What is the Working principle of Dozing valve?