Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is it mandatory statutory requirement of transformer oil
filtration annualy despite oil is withstanding required
dieelectrical strenth and all others parameters

Answer Posted / ramjeet singh

Yes; at least once in a year it should be filtered and
tested as per IS 1866-2000 to withstand not only BDV,
moisture but all the 9 test parameters; as at least we
should know what has happened in terms of oil
characteristics within a year.

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the meaning of neutral displacement ???

2792


v/f drive basic princeple

2542


Why hydropower stations are preferred solution for meeting peak loads in grids?

1054


What must be the minimum distance maintained between 2 Generators as per International standards?

2202


What is an alternator impedance value?

2905


I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.

1772


How to calculate the electrical load for a standard telecom BTS shelter and choose the DG set capacity for the same load?

3253


How will polarity test of Dy5 Transformer ?

2314


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1931


How to test REF relay testing for LV panel as per Kahramaa standard?

5000


How to Decide(calculate) Bush bar size for copper and aluminiam ?

2179


What is transformation ratio what it describes?

1765


is it possible to have dc motors on single chip

1884


why we change the direction of winding in rotor ?how we make the north and south pole?

2092


what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.

2003