Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Does power factor vary with speed?If yes, how?If not, why?

Answer Posted / roysayan01

I think pf doesnt vary wid speed. PF mainly depends on
excitation / field current. When overexcited the pf becomes
leading while it lags when underexcited in a synchronous motor.

BUT

cos(phi)=R/Z;
& z=(x^2 + R^2)^1/2
& x=2*pi*f*L
so if speed changes(n=120f/p), frequency changes &
accordingly x changes & as a result pf changes wid change in
speed.

Really am confused.wat do u think?

Is This Answer Correct ?    5 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How Diesel Generator start ?

2474


What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?

2060


can i use the six sigma method which is used in management area, in state estimation of power systems?

1910


How does a digital electronic meter work??????

2102


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1892


What is turn ratio of a transformer?

1301


What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?

1925


Why efficiency of generator is higher than motor at a particular load?

2131


Why arc quenching is used in Diode ?

2235


If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.

6269


What is the slip speed?

1148


what is the difference between circular wdg & ractangular wdg?

2099


HOW TO CALCULATE HV CABLE SIZING?

3281


Define characteristics impedance?

1185


What are the operation carried out in thermal power station?

1127