assume we are put both df/dt and vector surge relay in
same bus the df/dt relay setting is +5 hz an -5HZ. we want
operat the vector surge relay before the df/dt how i
calculate the setting of the vector surge relay.
Answer Posted / bhima dulla *maher king* porba
simple calculation buddy !!! Just set vector surge relay
setting to +4 to -4 Hz
| Is This Answer Correct ? | 3 Yes | 4 No |
Post New Answer View All Answers
Starting Time of LT & HT Motor
How to test REF relay testing for LV panel as per Kahramaa standard?
we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?
How eddy current generation support the idea of train braking?
previous year paper of ntpc bhel for degree in electrical enng
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
wht is embedded systems? what is new inthis field?
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
What is the power requirement of tamil nadu for one month?
what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?
how does the terminal voltage of transmission lines increase when a capacitor is connected???? This happens not only in transmission lines but also in all circuits. How??? When a capacitor is connected in a transmission line, capacitor also takes energy from the same supply. But how is it able to increase the terminal voltage??? Practically What sequence of events happen during increase in voltage???
There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
What is ST and specify its range of voltage.