Regarding MOS (maintenance override switch), I want to know
its function and its state ( 1 or 0 when not activated ).
An example will be very helpful..thank you.
Answer Posted / m.mohan
all are digital signals,hence DO or DI
ACTIVATED - GIVES O/P 1
NORMAL IT GIVES 0. Whatever we required, we can changes
the o/p.
abt MOS panel
In a industry having a lot of trip logic for
safety purpose or suitable process also.incase the txr or
further inst will make it a problem or mismatching value,we
would make it a loop for avoid trip conditions,after find
out& rectify it.In that operation can do it in a MOS
panel... simply change the selector switch,after take out
the job
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?
Q1]IF THE RANGE FOR FLOW IS -35 TO 125 WHAT WILL BE THE SPAN FOR ABSOLUTE AND FOR NORMAL? Q2]HOW TO CALIBRATE CAPILLARY TYPE LT? Q3]HOW MANY ERROR CALCULATIONS ARE THERE USED IN PROCESS INDUSTRIES? Q4]HOW TO CALIBRATE TEMPERATURE TRANSMITTER? Q5] HOW TO CALIBRATE LEVEL TROLL AND HOW TO CONNECT? Q6]PLEASE TELL ME THE BASIC FOR INSTRUMENTATION WHICH IS APPLIED FOR CALIBRATION AND FOR ALL? PLEASE MAIL THE ANSWER TO honest_yes@yahoo.in
what is the working principal of pribe
OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION
what is performance test.need defination
what is cems analyzer explain with principle and drawing ?
Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.
Difference between ultra sonic flow meter
how to calibrate 0- 150 psi presure gauge by dead weght tester
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Q- What are the application in which PNP transistor is preferred over NPN ?
What is the formula of vabration sesore. i mean how to covert mils to volt plz share if any body knows very argent : my mai is merajalam143545@yahoo.com
what is difference between HOT permit and cold permit
what is isloted barrier how it works and what are the main purpose.how it make safe area.
what is metal of piston ring