Is that Speed Probe and Vibration Probe sensors are same,if
yes what is the diff b/w them?
Answer Posted / ajith294
normally we are measuring vibration signals are amplitude,
frequecy and phase.
for this we are using the same probe.
vibration is measured as peak to peak, a measure of the
total excursion of the rotor or machine casing in 'mils or
micrometers'.
Frequency is measure of how fast a body is vibrating and is
used to identify the source of vibrations. frequency is
expressed in shaft rotative speed.
for calibrating or checking probe or transmitter using for frequency (rotation / min )
1. adjust gap voltage at zero (-10V)at TK 3
2. put some small sticker on wobbulating part.
3. increase the speed of wobulator (TK3)
3. your out put is measured from multi meter at HZ range
thanks
| Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
Name different types of bourdon tubes.
is there any digitel grevity meter availaible in the market by which we can measure specific gravity of a battery?
Gas equation
please send data bank of quetions answers on analytical instrumentation.
what is scale factor of proximitor & unit of the vibration.
What is difference between radial vibration and axial vibration explain in detail .
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
what is compensation? temprature & pressure
How to control flow variations in magnetic flow maters..... When i will provide proper earthing?
What is 1:1 redundancy ?
Why do we have earthing cable in branch cable and shield in the same cable?
Describe how to use megger to measure the earth resistance and insulation resistance
What is 3 selection available when configure the burnout protection for controller