Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between LT & HT Motors

Answer Posted / rajpurohit

fOR THE SAME POWER RATING THE SIZE OF THE LT MOTOR IS MUCH
BIGGER THAN HT MOTOR. But the insulaton level in HT motor
is more strenghter than LT motor. the current is very high
in same rating LT motor so the rating of the protection
device will be higher than HT type motor.
so generally we have taken HT motor in bigger size like
geater than 100 Kw. that can be taken in LT if HT is not
available there & space is availabe.

Is This Answer Correct ?    37 Yes 18 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.

2078


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

1834


What is the earth treantment procedure?

2061


why does connected a indutor with mnsformeretering core of current transformer ?

2123


Why 11kv to be generated in generation station

1651


Can we Co-ordinate relay in Load Break switch?

1944


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1968


what material is used in capaciter

1958


What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.

2167


what is the usage of microcontroller in the panel board?

2067


HOW TO CALCULATE HV CABLE SIZING?

3193


What are the conditions for sustained oscillator or what is backhouse criterion?

1119


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2201


what does a k rating in a transformer means?

2476


Where voltage are high and current to be interrupted is low the breaker preferred is:

2271