Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the main function of fuse?

Answer Posted / tippesh

The main function of fuse is to avoid the fault current or
short circuit current enter through the healthy circuit.
This is used to isolate the entire circuit from fault one

Is This Answer Correct ?    38 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between megger test equipment and contact resistance meter test instruments?

1308


slipring induction motor starting time Lrs operating why lrs starting time lrs outer body didn't get shock

1921


why does make gain margin and phase margin on same plot.?

2072


why current is constant on d.c?

2065


What happen to the transformer if the OLTC frequently used for lower and raise occured 50times daily?

2023


15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help

1552


What is nyquist contour?

1171


how to calculate the distance relay faulty zone?pls explain?

2028


How to decide whether A / B / C / D curve type MCB should be used?

2275


why swinburnes test cannot be performed on series machines?explain

2336


Where voltage are high and current to be interrupted is low the breaker preferred is:

2271


what are the factors to be considered while design the breaker either HT or LT??

1873


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

1118


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1856


can any tell me why slope 40% and 80% is calculated in differential protection?

1871