Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

We have AC-transformer 110/13.8kv,40MVA.If DC-Voltage=110kv
is applied in its primary what will happen?

Answer Posted / vasudeva rao

according to the faraday emf is developed in the winding
when there is a rate of change of flux is present.
(E=d&#934;/dt ) i.e time variant flux is present. but in d.c
current is constant i.e time invariant. here flux is
constant. so differentiation of constant is zero. i.e
d&#934;/dt=0. i.e e=0.


it means winding gets serious short circuit.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is voltage ratio of a transformer?

1167


What is the role of feedback in a closed loop control system?

1066


details of oil cell size of Breakdown voltage test of tranformer oil details as per Standardswith mushroom electrodes?

1866


what does mean of RCT and STR in diffrential CT?

4214


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2101


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

1942


What is method of calculating the fault current for a MDB, 50KW, 3PH, 415V, 50HZ?

2126


State kirchoff voltage law?

1114


what is the difference between ac motor and dc generator

1833


How may I enrol or get admission to your program?

1889


Why are cables rated for 40 KA for 0.25 Sec fault current rating?

1932


If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?

2294


how can calculation ate Amps for cabel. Ex-for 1sqmm wire hou many amps we can draw

2436


What is non-minimum phase transfer function?

1287


Where should the lighting arrestor be placed in distribution lines?

1122