why dead weight tester called dead weight tester.
Answer Posted / saparihar
In dead weight tester,
we put the weight on the weight stand of dead weight tester
putting weight is reference weight which is to be calibrate
and further we applied pressure by moving piston ,when
applied pressure and reference weight(Pressure)is equal at
this condition reference weight willbe zero(Dead).
therefore it is called dead weigh tester.
Is This Answer Correct ? | 34 Yes | 4 No |
Post New Answer View All Answers
what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?
Why thermo wells are used? What materials are used in thermo wells?
hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?
key phaser where is use and work
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...
flow transmitter formula?
why orfice is not used for main steam flow calculation
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
What is difference between Ionization heat and bimetallic heat
What is Cavitation in a control valve?
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744
How to Calibrate Radar Level Transmitter in Field
What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...
why fuse block is not used for AI signal?