why three phase three wire system probably did'nt have neutral

Answer Posted / vasudeva rao

in transmission system only 3phase 3 wire is used. neutral
is only run from the distribution side only not a
generation side and not a transmission side. so in
transmission no need to transmit a neutral through out the
length.

Is This Answer Correct ?    7 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw the wave shape of armature current in a generator subjected to a sudden three phase short- circuit at its terminals. Define various reactance of generator from this wave shape.

1632


how to setting voltage RTCC panel

1218


why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?

1539


Hello sir, pls send me hpcl technical test papers .i am. Appearing for the exam.

2242


Explain the operation of grid connected central solar inverter ?

1035






What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

1592


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

1657


What is inductance?

684


What is the lifetime of a Thyristor? Is there a recommended lifetime for thyristors after which they should be replaced?

2220


How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?

1924


What is difference between SMC supportg and Glass Fibre Reinforced Plastic Support.

1865


I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?

1397


how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc

1360


what are the advantage and dis-advantage of 3 phase 4 wire energy meter?

1466


i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?

1619