can any one give me the cost price of yokogawa & rosemount
transmitters
Answer Posted / ketas
it depends upon which type of transmitter you use.means
transmitter which have hart communication protocol its avg
price is 23000 to 32000.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
why is not useing in boiler skin thermocople
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
Why thermo wells are used? What materials are used in thermo wells?
what is the vital subject for scoring bhel exam&what is the question pattern
How to Calibrate Radar Level Transmitter in Field
, Instrument Index, P&ID review, I/O schedule, datasheet, DCS / Analyzers specifications, loop diagrams, hook-up drawings.
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???
1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?
What is Predictive Maintenance
Describe a time when you anticipated potential problems and developed preventive measures.
What are primary elements of measuring pressure? Which type of pressure can be measured by these elements?
what about your moleg in pogrees with company