Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the differences between MCB and MCCB ?

Answer Posted / md hasmat khan

(MCB) Stands for Miniature Circuit Breaker Which is used in
low current capacity MCB is not having the adjesement of
protection.
(MCCB) Stands for Moulded Case Circuit breaker Which is
used for High current capacity but MCCB over load, short
circuit, and earth fault.

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.

2694


Can RCD's used to protect the VVVF drive if not why.

2150


what is the circutor?why we use it ?

2330


Explain RLC circuit?

1174


What is the difference in calculating size of AC cables compared to calculating size of DC Cables? Usually DC Cables are larger than AC Cables although they have the same ampacity. Why is it?

1981


What are stable systems?

1088


What are the two segments of nyquist contour.

1106


Is the installation of the filter cloths necessary before spreading the gravels at the transformer yards?

1943


how pt is using

1947


What happen to the transformer if the OLTC frequently used for lower and raise occured 50times daily?

2047


what is mind in cable

2068


State the factors, for the choice of electrical system for an aero turbine.

1164


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1919


why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??

2297


DIFFERENCE BETWEEN NORMAL TRAFO AND THRISTER TRAFO?

2612